SAICE

ASCE Standard 21-00 Automated People Mover Standards- Part 3 Electrical Stations Guideways 2002

R332,89 Incl. VAT

Product Code: TD/ASC/AMPS3
This standard constitutes Part 3 of a three-part standard that aims to establish the minimum set of requirements necessary to achieve an acceptable level of safety and performance for an Automated People Mover (AMP) system.

Additional information

Weight 500 g
Author

ASCE

Publisher

ASCE

ISBN Number

978078440638

Contents

1 General

1.1 Scope

1.2 Existing Applications

1.3 New Applications

1.4 Reference Standards

1.5 Definitions

9 Electrical Equipment

9.1 General

9.1.1 Safety

9.1.2 Corrosion Control

9.1.3 Electrical System Protection

9.1.4 Grounding

9.1.4.1 Traction Power Grounding

9.1.4.2 Facilities and Structure Grounding

9.1.5 Redundancy

9.1.6 Design Life

9.1.7 Voltage Regulation

9.1.8 Capacity

9.2 Traction Power Substation Equipment

9.2.1 Interfaces with the Local Utility Company

9.2.2 Power Factor

9.2.3 Harmonics

9.2.4 System Monitoring and Alarms

9.2.5 Power Regeneration Equipment

9.2.6 Remote Monitoring and Control

9.2.7 Local Control

9.2.8 Restoring Power

9.2.9 Substation Facilities

9.3 Wayside Power-Collection Equipment

9.3.1 Guideway Mounted Power Distribution

9.3.2 Power Zones

9.3.3 Splice Joint Requirements

9.3.4 Expansion Joints/Sections

9.3.5 Power Rail Transitions

9.3.6 Insulators

9.3.7 Mounting

9.3.8 Power Rail to Earth Resistance

9.3.9 Power and Ground Rail Heating

9.4 Passenger Station Electrical Equipment

9.5 Uninterruptible Power Supply

10 Stations

10.1 Disabled Persons Access Requirements

10.1.1 Vehicle-Platform Gap

10.1.2 Detectable Warning Strip

10.2 Platform Edge Protection

10.2.1 Intrusion Prevention System

10.2.2 Intrusion Control System

10.2.3 Intrusion Detection System

10.3 Evacuation of Misaligned Trains

10.4 Emergency Lighting and Ventilation

10.5 Fire Protection

10.5.1 Fire Detection

PEOPLE MOVER STANDARDS-PART 3

10.5.2 Fire Containment 11

10.5.3 Fire Suppression 11

11 Guideways 11

11.1 Blue Light Stations 11

11.2 Intrusion Protection and Detection 11

11.3 Emergency Evacuation and Access 11

11.3.1 Tunnel Guideway 12

11.3.2 Surface Guideway 12

11.3.3 Elevated Guideway 12

11.4 Fire Protection 12

11.5 Signage 12

11.6 Emergency Lighting and Ventilation 13

11.7 Emergency Power Supply 13

11.8 Guideway Alignment 13

11.8.1 Clearances 13

11.8.2 Operating Equipment Interfaces 13

11.8.3 Drainage 13

11.9 Structural Criteria 14

11.9.1 Loads and Forces 14

11.9.2 Load Combinations 16

11.9.3 Design and Analysis 16

Similar Products